How To Clean Bottom Tray Of Goodman Air Conditioner
I of the main reasons why air conditioners demand to be replaced every so often is not clothing and tear. Information technology's because of all the dirt that accumulates over fourth dimension. By keeping your Goodman air conditioner well maintained non only volition you exist extending its life span, you'll also be saving coin on free energy bills.
If you desire your Air conditioning to operate at its highest efficiency, and then you'll demand to pay regular attending to information technology. Below are some tips you lot can use to keep your Air-conditioning in tip top condition. These tips are best applied correct before a absurd flavour begins. The following DIY tips utilize to the entire Goodman air workout unit. Every HVAC unit consists of either a furnace and heat pump or AC. No thing the type, they both have an interior and outside unit. The exterior unit consists of a compressor and condenser coil while the interior unit consists of a blower and an evaporator.
Step 1: Turn The Ability Off for your Goodman Ac Unit
The last affair any homeowner wants is to get electrocuted while maintaining their Goodman unit, and so ensure that you have switched the ability before y'all begin. For the interior unit turn off the power at the breaker box and employ the close-off box to close off the exterior unit's power.
Step two
This is where the real maintenance starts. Take off the fan cage that protects Goodman condenser's exterior unit using a wrench or a screw driver. You volition need to remove the fasteners before getting the fan grill or cage out of the style. In that location are a number of means y'all could take out the debris from the unit of measurement's interior. You could choose to employ either a wet or dry out vacuum or you lot might practise it by hand.
Step 3: Cleaning The Fins
To become rid of all the outside dirt you will demand to outset remove the unit'southward outer covers. Using a powerful shop vacuum's brush attachment, remove all the outside dirt. Follow this up with a gentle water spray from a garden hose. Have caution not to employ a pressure washer every bit that might damage the unit of measurement's fins. If you think that the fins are particularly muddy and need more attention, y'all can use a fin cleaning spray which is readily available in most home comeback shops.
Step four: Straightening The Fins
Sometimes the fins become aptitude which means that the exterior unit is working at a reduced efficiency. To remedy this you'll need to carefully use a fin-straightening tool or a butter knife. You lot need to be super careful when doing this as you wouldn't want to harm the embedded tubing.
Step 5: Make clean The Unit'due south Surrounding Area
Once you're through cleaning your unit of measurement, you should clear any castor in the unit of measurement'due south immediate vicinity as it might hinder air catamenia to the unit. Practise this at least ii feet in all directions. During the wintertime months, we recommend that you identify a plastic or plywood cover on peak of the unit to prevent droppings from falling in. Y'all shouldn't completely comprehend the unit'southward side though every bit information technology might lead to the build up of wet which in turn would crusade corrosion. The other reason why it'south a bad idea to completely encompass the sides is that you might end up with a vermin infestation problem.
Stride 6: You lot Demand To Level The Goodman Condenser
Nearly people don't know that one of the reasons why the compressor fails early is because the HVAC'southward exterior unit does not sit on level ground. You lot should regularly check to make sure that the pad on which the condenser unit sits isn't tipping to one side. In leveling the condenser unit of measurement, yous should employ rot-resistant shims. Note that if your oestrus pump is slightly sloped that shouldn't be cause for alert, a sloping estrus pump makes an allowance for defrost run-off in winter.
Step seven: Evaporator Whorl Cleaning
Once you're through cleaning out the HVAC'south exterior unit, it's at present fourth dimension to work on the interior portion of your unit of measurement. Yous might need to get some screws and bolts out of the way after finding the evaporator curl door. Next, you'll need to use a soft brush to go rid of any dust that might have accumulated on the coil. Once that's done use a no-rinse coil cleaner to spray the coil. The spray foams up and and then drips into the drain pan. Utilise a mixture of hot water, soap, and bleach to clean the drain pan. Finally, pour a cup of equal parts bleach and water down the bleed. To ensure that you lot drain pan stays cleaner for longer, nosotros recommend that you place a drain pan tablet in the pan. This acts as a measure against algae growth. If you lot notice that the bleach solution drains easily, you lot can skip over the next step. However, if it takes fourth dimension to drain, motion to the next step.
Step 8: Clean A Plugged Evaporator Drain
Humid air usually condenses on the evaporator'southward cool surface and turns to liquid h2o which then is exited using a drain tube via a drain pan. From the pan, the h2o flows into a drain tube which is typically routed into a pan below. Unfortunately, mold and algae can grow over time and plug the pipe which might lead to flooding. Yous'll need to employ a dry or wet vacuum to articulate the bleed. Have out the vacuum'southward filter first to avert impairment. When cleaning out the pipe you'll need to create an air tight space around the gap. You tin accomplish this either by using duct tape or holding a piece of cloth over the gap.